Quickie Groove 55
.EMS
14.4.2 Cleaning controls
Should the control of your wheelchair become soiled or dirty, it
can be wiped with a damp cloth with a dilute disinfectant until
clean.
WARNING!
This is important should the wheelchair be used by more than
one person to ensure there is no cross infection.
Speciality controls
WARNING!
Ensure that wafer boards, joysticks (all variants), head arrays
and switches (all variants) are cleaned with a mild disinfectant
and a cleaning cloth to avoid any cross infection possibilities.
Following removal from chair regularly wash the sip and puff
mouth piece and tube to maintain cleanliness and functionality.
WARNING!
Ensure control is switched off before cleaning.
14.5 Lighting bulb exchange procedure
If the bulbs of your lights and indicator system show a defect,
indicated through a double speed flash of the indicating LED
on the hand control, please proceed in the following way:
Front lights and indicators (TUV and LED light type):
Use a cross screw driver to release the screw of the light or
indicator glass. Take the glass off. This gives you access to the
bulbs.
For the TUV lights 12V/3W bulbs with an E12 thread are
required
For the TUV indicators 12V/5W bulbs with a 90° bayonet
socket are required
For the LED lights and indicators specific 12V bulbs with an
E12 thread are required. Please contact Sunrise Medical
for spares.
Rear lights and indicators:
TUV lights: Lift the red or orange glass of the light carefully off
the socket. If a bulb needs to be replaced 12V/5W cylindrical,
capless is required.
For the LED lights and indicators specific 12V bulbs with
an E12 thread are required. Please contact Sunrise Medical
for spares.
NOTE: Use Sunrise Medical authorised spare parts only.
Be advised that all lighting circuits are electronically protect-
ed. In the event of a short circuit current will be limited to
a safe level. Once the fault is removed the system resets
automatically.
14.6 Electrical connections
When inspecting electrical connections, pay attention to the
battery connections, the connection of batteries to power loom
and plug in sockets for the joystick, control box and lights and
indicators.