Quickie Groove 27
.EMS
7.8 Actuator button and LEDs:
Depending on whether your wheelchair is fitted with one or two
actuators the operation of these buttons will differ.
Wheelchairs with one actuator
Depressing either actuator button will enter actuator adjustment
mode. This will be indicated by the illumination of both actuator
LED’s. Actuator adjustment can then be made by deflecting the
joystick forwards or backwards. To re-enter drive mode, depress
either actuator button.
Wheelchairs with two actuators
Depressing either actuator button will enter actuator adjustment
mode. If the left button is depressed the associated LED will be
illuminated, and deflection of the joystick will adjust the actuator
motor connected to that channel. If the right button is depressed
the associated LED will be illuminated, and deflection of the
joystick will adjust the actuator motor connected to the other
channel.
To re enter drive mode, depress the selected actuator button, as
indicated by the associated LED.
It is also possible to select the other actuator by left or right
movements of the joystick.
7.9 Charging and programming socket:
WARNING!
This socket should only be used for programming and charging
the wheelchair. This socket should not be used as a power supply
for any other device. Connection of other electrical devices may
damage the control system or affect the EMC performance of
the wheelchair.
NOTE: See Section 12 about charging.
The programming socket will enable an approved Sunrise
Medical authorised dealer to re-programme your chair and also
gain useful information when tracing any faults. When the chair
leaves the factory, the parameters of the controller are set to
default.
To programme the controller you need a special programming
device (handheld or PC software), which is available through
your Sunrise Medical authorised dealer.
WARNING!
Programming the controller of the wheelchair is only allowed
through authorised personnel trained by Sunrise Medical.
Incorrect controller settings could cause driving outside the safe
limits and could result in damage or injury.
NOTE: Sunrise Medical does not accept responsibility
for damages which result from unexpected stopping of the
wheelchair or inappropriate programming or unauthorised use
of the wheelchair.
7.10 VR2-L
There are common controls between the VR2 and the VR2-L
control systems where a control differs it will be described
below. All common controls can be found on the previous
page.
7.11 Lights and indicators:
The wheelchair can be equipped with lights and indicators.
Where lights are not factory fitted, they may be fitted as an
optional extra by an approved Sunrise Medical authorised
dealer.
WARNING!
Ensure that the lights and indicators are functioning correctly
and lenses are clean before going outdoors at night.
7.12 Indicators:
To turn on the wheelchairs indicators operate the required button
either left or right, the associated LED will also illuminate in
sequence with the indicators.
If the LED flashes rapidly either a total short circuit, a single
lamp open circuit or a total open circuit in the left or right
indicator circuit has been detected. If this is the case, Contact
your Sunrise Medical dealer.
Depress the indicator button to turn off the indicator and the
associated LED.
7.13 Main lights:
To turn on the wheelchairs lights operate this button, the
associated LED will illuminate continuously.
If the LED flashes a short circuit in the lighting circuit has
been detected. If this is the case, Contact your Sunrise Medical
dealer.
Depress the light button to turn off the lights and the associated
LED.
7.14 Hazard warning lights:
To turn on the wheelchairs hazard warning lights operate this
button, the associated LED will flash at the same rate. The left
and right turn indicator LEDs will also flash.
If the LED flashes rapidly either a total short circuit, a single
lamp open circuit or a total open circuit in the entire indicator
circuit has been detected. If this is the case, Contact your
Sunrise Medical dealer.
Depress the hazard warning button to turn off the lights and the